The Energy Recovery Ventilator (ERV) and Heat Recovery Ventilator
(HRV) are fresh air exchange appliances that take fresh air into
a dwelling, clean and evenly circulate the fresh air and expel stale,
polluted air while controlling humidity and minimizing heat loss/gain.
The current trend toward sealing
(tightening) houses to reduce air and moisture infiltration makes
them more energy-efficient and less costly to own. However making
them very tight, but with poor ventilation, can create many indoor
air quality problems including mold, persistent and objectionable
odors, and what is commonly known as "sick building syndrome."
While opening windows for ventilation is an option, this also defeats
the purpose of building a tight home in the first place. It is advisable
that such houses also have a controlled way of moving fresh air
into the house and removing stale/contaminated air from it. Such
a system must be able to maintain air circulation while minimizing
energy loss. One of the better ways of accomplishing this is with
Enthalpy Recovery Ventilators (ERVs aka. Energy Recovery Ventilators).
Transferring a little water vapor across the core is often desirable
because in extremely cold weather [consistently below 20oF (-7oC)],
the water vapor from the exhaust air of an HRV can freeze the core
and the exhaust vent to the outdoors. If this should happen, the
ventilation rate is severely reduced. HRVs are also known for drying
the house air to uncomfortable levels in climates where winter can
last months.
Since an ERV (using a Mitsubishi
Lossnay Core) transfers some of the moisture from the exhaust
air to the usually less humid incoming winter air, the humidity
of the house air stays more constant. This also keeps the heat exchanger
core warmer, and so helps minimize problems with freezing. Some
systems also have an electric heating element for defrosting the
exterior vent to minimize freezing in that location.
In the summer, ERVs may help to control humidity in the house by
transferring some of the water vapor in the incoming air to the
theoretically drier air that's leaving the house. If you run an
air conditioner in the summer, an ERV generally offers better humidity
control than an HRV.
Researchers have found that some of the water vapor can condense
on the cool ductwork interiors and thus promote mold growth. This
is especially a problem for buildings with over-sized cooling equipment
or during partial cooling loads (i.e., when it's warm and humid
outdoors, but still not hot enough for the equipment to turn on
for more than a few minutes at a time.)
All properly designed residential ventilating systems should be
able to at least move about one third of an air change per hour
(ACH) or 15 cubic feet per minute (CFM) per person. For example,
if your house has 2500 square feet (232 square meters) of floor
space, and you have 8 foot (2.44 meter) ceilings, then the ventilation
system would move approximately 189 CFM.
However, designers should not use the 1/3rd ACH guidelines as a
"hard-and-fast-rule." There will be times in the house
when more ventilation is desired (i.e., at a party with many people
present) and times when little ventilation is wanted (i.e., when
no one is home). To assist the occupants in this effort many manufacturers
offer a variety of control strategies. A few of the more useful
features are: water vapor and carbon monoxide sensors; multiple
fan speeds; and programmable timers. Most manufacturers also offer
high efficiency air filters to trap pollen and other undesirable
pollutants from the outdoors before they enter the system. Some
also offer pre-heater or pre-cooler coils to make the incoming air
more comfortable during extreme weather conditions.
There are some small wall- or window-mounted models, but the majority
are central models with their own duct system. To save on installation
costs, many installations share existing ductwork.
An energy recovery ventilation system should be designed as simply
as possible for economy of installation and energy efficiency. Duct
runs should be as short and straight as possible. The correct size
duct is necessary to minimize pressure drops in the system and thus
improve performance. Insulate ducts located in unheated spaces to
at least R-9, and seal all joints with duct mastic (never use ordinary
duct tape on ducts.)
There are several ways of routing the ducts around the house. In
general you want to have a supply and return duct for each bedroom
and one for each common area. Do not locate returns within 10 feet
(3.05 meters) of an oven or cooktop, as vaporized grease could clog
the heat exchanger core and contaminate the ducts. Locate the ERV
itself in an easily accessible area and as centrally as possible
to all of the rooms. A sewer drain or condensate pump may be necessary
for removal of water that the core extracts from the air during
cold weather. Locate the outside air intake as far from driveways,
clothes dryer and furnace vents as possible. Keep all supply and
exhaust vents at least 10 feet (3.05 meters) from each other.
In general, simplicity is key to a cost-effective installation.
Sophisticated and complex systems are not only more expensive to
buy but they are generally more maintenance intensive and often
consume more electric power. For most houses, attempting to recover
all of the energy in the exhaust air will probably not be worth
the additional cost. These types of ventilation systems are still
not that common, and many heating, ventilation and air conditioning
contractors may not have very much technical expertise and experience
with them.
Source sited from:
http://www.eere.energy.gov/consumerinfo/refbriefs/ea5.html
Renewaire renewair newair newaire
energy recovery ventilators energy recovery ventilation ventilator
Lossnay ERV HRV ventilater IAQ indoor air quality heat recovery
ventilation ventilators air-to-air heat exchangers make-up air Mitsubishi
Lossnay enthalpy exchangers residential ventilation commercial
|